news

What's volume control damper machine?

2025-02-28 17:00

Introduction to the damper forming machine


The vcd frame machine is a highly efficient equipment specially used for cold bending and forming of metal materials. Its main purpose is to produce the frames of volume control dampers (VCD), which are widely used in air flow management in buildings and industries. The finished products of the volume control damper frame machine include not only metal shell distribution boxes and electrical cabinet frames, but also VCD frames for regulating and controlling air flow.

 

volume control damper frame machine


Purpose of vcd frame machine


The core function of the vcd damper machine is to process metal coils into frames of various shapes and specifications. Its main uses include:

 

1. Air flow control: The damper is a device used to stop or regulate the air flow in the air duct, which can effectively control the air flow in the heating, ventilation and air conditioning system, thereby improving energy efficiency and comfort.

 

2. Adapt to different environments: VCD can be used to cut off the central air conditioning in unused rooms, or adjust the air flow to control the temperature and climate of each room to meet the needs of different use spaces.

 

3. Versatility: In addition to being used in ventilation systems, vcd frame machines can also be used to produce metal enclosure distribution boxes and electrical cabinet frames, which are suitable for a variety of industries such as power, automation and construction.

 

vcd frame machine


Application of vcd frame



The vcd frame has a wide range of applications, mainly including the following aspects:

 

- Central air conditioning system: In central air conditioning systems, dampers are used to adjust the distribution of cold air to ensure uniform indoor temperature.

 

- VAV (Variable Air Volume) system: In variable air volume systems, dampers can flexibly adjust air flow to optimize energy consumption and indoor environment.

 

- Air handling unit: In air handling units, dampers can be used to control the inlet and outlet of air to ensure stable air quality and temperature.

 

- Building ventilation system: In the ventilation system of a building, dampers help manage air flow and improve indoor comfort and energy efficiency.

 

volume control damper frame machine
vcd frame machine
volume control damper frame machine


Workflow of volume control damper frame machine


The working process of the vcd frame machine is as follows:


Unwinding: The metal coil is unwound by the decoiler and is ready for subsequent processing.

 

Forming: In the roll forming machine, the flattened metal coil is cold-bent into a frame of a specific shape. This step is the core part of the vcd frame machine.

 

Punching: At the punching station, the formed frame will be punched according to the design requirements to facilitate subsequent assembly and installation.

 

Cutting: Finally, the punched finished product is cut through the shearing station to form the required final product.

 

vcd frame machine


Advantages of volume control damper frame machine

 

volume control damper frame machine

Full automation

The entire production line is automated, reducing manual intervention and improving production efficiency.

vcd frame machine

Good forming effect

The use of advanced forming technology ensures good forming effect and beautiful product appearance.


volume control damper frame machine

High precision

High-precision processing technology ensures that the size and shape of the vcd frame meet the design requirements, reducing the need for subsequent processing.

vcd frame machine

Good machine stability

After strict material selection and process design, the vcd frame machine maintains stability during long-term operation and reduces the failure rate.


volume control damper frame machine

Fast and adjustable speed

The vcd frame machine runs fast and adjustable, and can be flexibly adjusted according to production needs, which improves the flexibility of production. 

 

Different types of vcd frame machines


KINGREAL's volume control damper frame machines can produce various types of dampers, including dampers with flanges inside, flanges outside, and dampers without flanges. These different types of dampers adapt to different installation environments and customer needs.

 

Vcd frame machine with flange inside


This type of damper design embeds the flange inside the frame, which is suitable for installation environments with small spaces. Its advantages are:


- Improved sealing performance: The internal flange design can better connect with other equipment, improve the sealing effect, and reduce air leakage.

- Simple appearance: The flange is hidden inside, making the overall appearance more simple and beautiful.

vcd frame machine

Vcd frame machine with flange outside


The damper design with flange outside makes installation more convenient and is suitable for equipment connection with larger space. Its advantages include:


- Easy to install and maintain: The exposed flange design makes the connection between the damper and the pipeline more intuitive, which is convenient for installation and subsequent maintenance work.

- Strong applicability: Suitable for a variety of pipe connection methods, compatible with different installation requirements.

volume control damper frame machine

Vcd frame machine without flange


Damper without flange is mainly used in specific application scenarios, suitable for situations where it is necessary to simplify the connection and reduce costs. Its advantages are:


- Reduced cost: It eliminates the design and manufacturing costs of flanges and is suitable for projects with limited budgets.

- Lightweight and flexible: The flangeless design makes the damper lighter and easier to transport and install.

vcd frame machine

Related News

More >
Get the latest price? We'll respond as soon as possible(within 12 hours)
  • This field is required
  • This field is required
  • Required and valid email address
  • This field is required
  • This field is required